FIRE TECHNOLOGY TO A HIGHER POWER

FIRESHELL®
Fire Extinguishing, Intumescing, Insulative Coating

Part Number: F5E

FIRESHELL® (F5E) is a proprietary non-flammable, intumescing (expands up to 2000%), flexible, ductile, elastomeric coating that is suitable for interior or exterior use. It is a non-toxic, water based, drain safe, no fuming product.

FIRESHELL® passes ASTM E119 - 1 and 2 hour wall tests, UL263 - 1 and 2 hour wall tests, and E84 class A certified. It is a waterbased one part coating system that comes light gray and black but can be custom colored. This coating can be latex or oil based topcoated.


Approvals / Certifications:
  • SFI Spec 54.1 Test Certification
  • Meets UL 263/ASTM E 119, 1 Hour Wall, 1/2 inch gypsum with 12 mills DFT.
  • Meets UL 263 ASTM E 119, 2 Hour Wall, 1/2 inch gypsum with 18 mills DFT.
  • Meets SWRI 99-02 Crawl space Ignition Barrier test over foam insulation with 8 mils DFT.
  • Meets ASTM E 119 and UL 263 coated closed cell spray foam 15 minute wall assembly test with 16 mils DFT. 16 Minute Rating.
  • Meets ASTM E 119 and UL 263 coated closed cell spray foam 15 minute wall assembly test with 21 mils DFT. 34 Minute Rating.
  • Meets ASTM E 84 and UL 723, Class A and 1/2 hour noncombustible ratings. Meets Urban Wildlife Codes.
  • Meets ASTM E 84 and UL 723, Class A, 15 mils DFT on cement board. Flame 0, Smoke 0.
  • Water Vapor Transmission: 0.5 grains/sf/hr, ASTM E 96.
  • Water Vapor Permeance: 0.9 perms, ASTM E 96.

Meets weatherability requirements for exterior coating as follows:
  • ASTM D 522: Flexibility over conical mandrel
  • ASTM D 2486: Scrub resistance
  • ASTM D : Abrasion, falling sand
  • ASTM D 2794: Impact resistance
  • ASTM D 4541: Adhesion, pull off strength
  • ASTM D 2243: Freeze thaw resistance
  • ASTM G 153: Accelerated weathering - 1000 hrs, 8 hours UVA 340@ 60c
  • ASTM D 412: Tensile, elongation properties
  • ASTM D 6904: Wind driven rain
  • ASTM D 3273: Mold resistance
  • FTMS 141 M4494: Sag resistance
  • ASTM D 4585: Moisture resistance, 100 hours
  • ASTM D 1729: Color change
  • ASTM D 4214: Degree of chalking
  • ASTM D 661: Degree of cracking


You will need a Username & Password to view our certification materials.
Please CALL: 860.767.8772

SFI 54.1 thermal, flame barrier, fire extinguishing & vapor fire resistance specification

MISCELLANEOUS PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
SFI 54.1 Thermal, Flame barrier, fire extinguishing & vapor fire resistance specification F5E (NASCAR)
F1ER (NHRA)
TEMPROTEX See Report Multiple scenario specification: fire extinguishing, fire barrier, thermal barrier extreme duty tests for worldwide race applications various composite, carbon fiber and plastic substrates First approved fire extinguishing fire barrier approved for worldwide racing
Tested in accordance with SFI 54.1
Supplemental Product Data



TPR2 Corp. © 2017. All Rights Reserved.
Back to page top Up Arrow