FIRE TECHNOLOGY TO A HIGHER POWER

General Test Reports

ASTM E84 Test Reports

ASTM E84 PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
Class 'A' F1 Non Flammable Elastomeric Paint Upto 15 mils Interior/Exterior Non Flammable Paint Cement Board Flame:0 , Smoke:0
E84-10 IB4 FIRESHELL®
Ignition Barrier
7 mils Standard test for surface burning characteristics of building materials Fiber cement board and select grade red oak flooring Flame:0 , Smoke:20
E84 F10E FIRESHELL®
Thermal Barrier
15 mils Standard test for surface burning characteristics of building materials Fiber cement board and select grade red oak flooring Flame:5 , Smoke:20
Class 'A' & extended 30 min. F1E FIRESHELL®
ULTRA
15 mils Standard test for surface burning characteristics of building materials Douglas Fir framing lumber Class "A" 30 minute non-combustible
E84 F1E FIRESHELL® Ultra 15 mils Standard test for surface burning characteristics of building materials Cement Board Flame:0 , Smoke:0
Class 'A' PR10 FR Polyester NA Standard test for surface burning characteristics of building materials Ultra Low Petroleum Polyester Flame:15 , Smoke:45
Class 'A' PR10 Impregnated Polyethylene Panel NA Standard test for surface burning characteristics of building materials 50% TPR2 Fire Retardant Impregnated Polyethylene Panel Flame:5 , Smoke:5


Miscellaneous Test Reports

MISCELLANEOUS PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
ISO 21487 and ABYC H33 Fuel tank fire & Static pressure test F1ER F1ER coating marine fuel tank 18 mils Fiberglass Fuel Tank coated with TPR2 F1ER in tumescent coating 270 gallon Fiberglass fuel tank Pass
LEED Credit Compliance NA Misc. NA Appropriate LEED's Sections for credit NA AQMD Super Compliant
EPA Method 24 - VOC test F10E FIRESHELL® NA VOC test for LEED Compliance NA < 1g/l
EPA Method 24 - VOC test IB4 FIRESHELL® NA VOC test for LEED Compliance NA < 1g/l
SFI 54.1 Thermal, Flame barrier, fire extinguishing & vapor fire resistance specification F5E (NASCAR)
F1ER (NHRA)
TEMPROTEX See Report Multiple scenario specification: fire extinguishing, fire barrier, thermal barrier extreme duty tests for worldwide race applications various composite, carbon fiber and plastic substrates First approved fire extinguishing fire barrier approved for worldwide racing
Vapor Barrier Test F1E FIRESHELL® See Report To determine the moisture vapor transmission characteristics of a coating film Porous Test Charts WVT = 0.5 grains/ft2/hour
WVP= 0.9perms
Durability Test F10E FIRESHELL® See Report To determine the performance properties of NFPA 286 thermal barrier / intumescent coating NA Passed
Durability Test BMS TC FIRESHELL® for
Bayseal® Foams
See Report To determine the performance properties of intumescent coating for
Bayseal® Foams
NA Passed
Durability Test BMS IC FIRESHELL® for
Bayseal® Foams
See Report To determine the performance properties of ignition barrier for
Bayseal® Foams
NA Passed
Durability Test IB4 FIRESHELL® See Report To determine the performance properties of ignition barrier coating. NA Passed
Durability Test JM TC FIRESHELL® for JM Corbond® Foams See Report To determine the performance properties of intumescent coating for
JM Corbond® Foams
NA Passed
Durability Test F4 Non-Flammable Exterior Paint See Report To determine the performance properties of elastomeric high build coating NA Passed
FSIS Incidental Contact F1E FIRESHELL® NA USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" NA Compliant with USDA Regulations
FSIS Incidental Contact F1EP STRUCTURE SAVER® NA USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" NA Compliant with USDA Regulations
FSIS Incidental Contact F5E TEMPROTEX NA USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" NA Compliant with USDA Regulations
FSIS Incidental Contact F10E FIRESHELL® NA USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" NA Compliant with USDA Regulations
Mold Resistance IB4 FIRESHELL® NA ASTM D-3273-05 Resistance to growth of mold on the surface of interior coatings in an environmental chamber. ASTM D-3274-02 "Evaluating degree of surface disfigurement of paint film by fungal growth or soil and dirt accumulation Gypsum Wallboard No Mold Growth
Mold Resistance F1E FIRESHELL® Ultra NA ASTM D-3273-05 Resistance to growth of mold on the surface of interior coatings in an environmental chamber. ASTM D-3274-02 "Evaluating degree of surface disfigurement of paint film by fungal growth or soil and dirt accumulation Gypsum Wallboard No Mold Growth
Mold Resistance F10E FIRESHELL® NA ASTM D-3273-05 Resistance to growth of mold on the surface of interior coatings in an environmental chamber. ASTM D-3274-02 "Evaluating degree of surface disfigurement of paint film by fungal growth or soil and dirt accumulation Gypsum Wallboard No Mold Growth


NASA STD6001 Test Reports

NASA STD6001 PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
NASA STD6001 F1E FIRESHELL® NA Flammability, odor, off gassing, and compatability requirements and test procedures for materials in environments that support combustion Steel Passed


ASTM E162 Test Reports

ASTM E162 PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
ASTM E162 M1 Flexible FIRESHELL® Mastic NA Surface flammability of materials using radiant heat energy source NA Class 'A'
ASTM E162 M1 Neotard 9300 Nonflammable Foam NA Surface flammability of materials using radiant heat energy source 3/4" fire stable foam Class 'A'
ASTM E162 M1 Neotard 9300G Nonflammable Foam NA Surface flammability of materials using radiant heat energy source 1/2" fire stable intumescing foam Class 'A'